Text from the interactive explanation
The functional impact of myofiber macroscopic organization and disarray in computational models of the murine heart
Carlo Guastamacchia, Roberto Piersanti, Francesco Giardini, Raffaele Coppini, Cecilia Ferrantini, Luca Dede', Leonardo Sacconi, Francesco Regazzoni
Mouse heart · computer simulation study
Computer “digital twins” of hearts need a map of which way every muscle fiber points — a map that can’t be measured inside a living body. This study gave a simulated mouse heart its real, microscope-imaged fibers and compared them with smoothed and rule-generated maps.
Colour = helix angle α: 0° runs around the heart, ±90° apex-to-base. Mouse heart, ≈8 mm across.
MEASURED imaged in a real (ex vivo) mouse heart
DERIVED computed from the measured fibers or from the heart’s shape
SIMULATED output of the authors’ computer model
SCHEMATIC our drawing to explain an idea — not data
What you’re seeing above: each of the ≈34,000 short strokes is the fiber direction at one point of the two ventricles of a mouse heart (sampled every 0.2 mm), coloured by its helix angle. The glow replays one simulated 200 ms heartbeat, slowed down: a spark follows the simulated electrical wave from point to point, then the muscle lights up with the simulated active tension. The gentle inward squeeze is only an illustration.
Muscle pulls along its grain
Heart muscle is built from long cells (cardiomyocytes) lined up end to end into fibers . A fiber pulls mainly along its own length, and electrical signals also travel faster along fibers than across them. So the direction of the fibers decides which way the wall gets pulled.
Fibers run left–right: the strip shortens left–right.
In the model, active force acts along the fiber only — the paper’s Eq. 20 with the stress factors set to mf = 1, ms = mn = 0. (Those knobs return in section 5.)
Dots: individual mesh points of the mouse LV free wall at mid-height; band: middle half of the values; line: average (computed on doubled angles). Turning angles computed for this page.
What is the helix angle α?
Look at the heart from outside and pick a point. The helix angle α is the angle between the fiber there and the line running around the heart, like a line of latitude on a globe. α = 0° means the fiber runs around the heart; α = ±90° means it runs from the apex (the tip) to the base (the top). +90° and −90° are the same direction — a fiber has no head or tail — which is why they share a colour on this page.
In the imaged heart the fibers twist steadily as you go through the wall, like the plies of a rope. The rule-based map turns in an almost straight ramp (the rule interpolates linearly through the wall). Heavy smoothing (ℓ = 1.0–1.5 mm) flattens the twist toward 0°.
Mess and map
Up close, the imaged fibers are not perfectly tidy: neighbouring fibers point in slightly different directions. This local scatter is called fiber disarray . Underneath it sits the big, smooth twist — the macroscopic architecture . To pull the two apart, the authors blurred (smoothed) the measured fiber map over a radius ℓ : what survives the blur is the architecture; what the blur removes is the disarray.
Mean angle from the imaged fibers: 0° (this is the imaged reference)
3 mm × 3 mm window — hover, tap or use arrow keys on the slice to move it.
Stroke = fiber direction within the slice plane; a short stroke means the fiber points out of the page. Colour = helix angle α. The thin crescent on the right is the right-ventricle (RV) wall; the big “V” is the left-ventricle (LV) cavity, apex at the bottom. Mean angles are computed for this page over all mesh points of the whole heart.
Small blurs (ℓ = 0.10–0.25 mm) mostly wipe out the local jitter. By ℓ = 1.0–1.5 mm the blur reaches across a good part of the wall and the twist itself starts to fade. The rule-based map is regular by construction: it contains no disarray at all.
Why you can’t just average angles
Fibers have no head or tail. A fiber at +80° and one at −80° are only 20° apart — both run nearly apex-to-base. Average the numbers and you get 0°: a fiber running around the heart, perpendicular to both. Drag the sticks to try it.
The paper’s fix: put each angle on a circle at twice the angle, as the point (sin 2α, cos 2α). Opposite directions (α and α + 180°) land on the same point. Average the points, then halve the angle of the result:
α = ½ · atan2( mean sin 2α , mean cos 2α )
This page’s colour compass uses the same trick: colours repeat every 180°, so +90° and −90° share a colour.
The blur
The smoothing is a Helmholtz filter applied to both coordinates over the whole heart mesh:
−ℓ² Δη + η = η
It works like a soft brush of radius ℓ: each point becomes a weighted average of its neighbourhood, with weights falling off as e−r/ℓ/(4πℓ²r). Mapping back gives the smoothed angle α, and the measured angle splits into
α = α + ε (architecture + disarray)
α(x) = α(x, ℓ) + εα(x, ℓ) — measured angle = macroscopic part + disarray (12)
ηsin = sin 2α, ηcos = cos 2α — the doubled-angle coordinates (13)
−ℓ² Δη + η = η in Ω, ∇η · n = 0 on the boundary — the Helmholtz filter, solved for both coordinates with the finite element method (14)
η(x) = ∫ h(|x − x′|) η(x′) dx′ — the same filter written as a convolution, in an unbounded domain (15)
h(r) = e−r/ℓ / (4πℓ² r) — its kernel (Green’s function) (16)
α = ½ atan2(ηsin, ηcos) — back to an angle (17)
The same procedure is applied to a second fiber angle (the intrusion angle γ); the fiber directions are then rebuilt from the smoothed angles.
Three tests — predict first
The authors put each fiber map into the same full computer model of the mouse heart: an electrical wave triggers calcium release; calcium makes the muscle generate active tension along its fibers; the tissue deforms; and a simple model of the blood circulation pushes back with pressure. Then they compared three things.
Which do you think cares most about the fiber details?
Activation time — the moment the electrical signal reaches each point — simulated with four fiber maps and shown on the long-axis slice. In the model, electrical conductivity along fibers is set to twice that across them.
Imaged · total 11.78 ms
ℓ = 0.25 mm · total 11.69 ms
ℓ = 1.0 mm · total 12.60 ms
Rule-based · total 12.33 ms
Lit = already activated (colour bands every 1 ms; white = the wavefront right now). Dark = not yet reached. “Total” is the total activation time Tmax over the whole heart.
With the muscle’s own force switched off, the model inflates both ventricles step by step from 0 to 37.5 mmHg and records how much the left ventricle (LV) holds — like testing how stretchy a balloon is.
“Springs around the heart”: the outer surface is held by springs and dampers standing in for the pericardium, as in the heartbeat model. “Free outer surface”: no springs, base held fixed — used by the authors to rule out the boundary as the cause.
Test 3 · The squeeze — active heartbeat. Make your prediction above (or skip) to unlock this result and the verdicts for Tests 1 and 2.
One heartbeat, millisecond by millisecond
A pressure–volume (PV) loop plots the blood volume inside a ventricle against the pressure in it during one beat. Going round anticlockwise: filling (volume rises at low pressure), isovolumic contraction (valves shut, pressure shoots up), ejection (blood leaves, volume falls), isovolumic relaxation (valves shut, pressure drops). The simulated mouse beat lasts 200 ms — about 300 beats a minute.
ILLUSTRATIVE cup fill ∝ volume, needle ∝ pressure
Active tension is the simulated force per area generated by the muscle, averaged over the whole heart. In the model the RV muscle is set to half the LV’s strength, and the paper’s analysis focuses on the LV.
Can a knob fake the mess?
Real fiber maps are rarely available, so modellers start from a tidy map and turn a knob to make up for the missing disarray. The paper tested two common knobs:
Contractility aXB (cross-bridge stiffness): one number that scales how hard all the muscle pulls — the active tension is Ta = aXB · G([Ca²⁺], SL). Baseline: 23 MPa in the LV; the RV gets half.
Stress factors SF = (mf, ms, mn) : how the active force is shared between the fiber direction f and the two cross-fiber directions — the sheet s and the normal n. SF = (1, 0, 0) means pull only along the fiber.
Your goal: land the simulated LV loop on the imaged baseline (dashed).
SIMULATED only settings the authors actually ran are offered.
As the paper reports, extra force in the normal direction, SF = (0.99, 0, 0.14), shifts the loop to the left (EF 58.5%), while extra force in the sheet direction, SF = (0.99, 0.14, 0), shifts it to the right (EF 42.7%). Several settings bring the global numbers close to the imaged baseline — the loop test passes. But does the tissue move the same way inside?
Zoom in: same loop, different tissue
Strain measures how much each small piece of tissue is deformed compared with its resting shape. The paper maps three summary numbers of the strain (invariants of the Green–Lagrange strain tensor): I1 ≈ overall stretch or squeeze (dilatation), I2 ≈ change of shape (distortion, shear), I3 ≈ change of volume.
The silhouette is the real slice outline; the pins and remarks summarise the paper’s text. Pin colours: white = reference, green = matches the imaged baseline, amber = partly, red = differs, grey = not singled out by the paper.
Scoreboard: the loop versus the tissue
Loop columns: differences from the imaged baseline, computed for this page from the simulated LV traces. Tissue column: the paper’s qualitative description.
The paper’s verdict: both knobs can recover a baseline-like PV loop, but not the local strain. Lowering contractility, despite being a crude fix, matches the local strain better than adding cross-fiber force. Starting from the smoothed imaged map beats starting from the rule-based one — the macroscopic architecture dominates.
What this changes
Back to the opening question. For a digital twin, a good picture of the big fiber organisation seems to be enough to get the electrical activation pattern right. Mechanics is different: active contraction and local strain need the right architecture and an honest treatment of disarray — and the common knobs that fix the global loop do not fix local deformation.
The authors’ outlook: more faithful models will likely need rigorous “upscaling” that links microscopic fiber distributions to an effective active stress (their planned future work), and tests on larger animal and human geometries once high-resolution whole-heart fiber datasets exist for them.
Limits to keep in mind
One heart. A single mouse heart geometry: specimen-specific factors, tissue preparation and imaging uncertainty may influence the results.
Mostly the left ventricle. The RV has a thin wall, works at lower pressure and its fiber data have a lower signal-to-noise ratio, so the conclusions are better supported for the LV.
Healthy activation only. Disease such as scar or fibrosis may amplify the role of fiber architecture.
Not directly transferable to humans. The framework is species-agnostic, but the numbers do not translate directly.
Simulated function. All pressures, volumes, activation times and strains come from the computer model, calibrated partly on measurements from this same heart and partly on literature data.
Mouse, not human
Source, data and credits
Guastamacchia C, Piersanti R, Giardini F, Coppini R, Ferrantini C, Dede’ L, Sacconi L, Regazzoni F (2026). The functional impact of myofiber macroscopic organization and disarray in computational models of the murine heart. PLOS Computational Biology 22(9): e1014807. doi:10.1371/journal.pcbi.1014807 · CC BY 4.0.
Fiber fields, activation times and pressure–volume traces: authors’ open dataset (Zenodo, doi:10.5281/zenodo.20825848, CC BY 4.0), subsampled and unit-converted for this page. All graphics are original.
Fibers imaged in one cleared ex vivo mouse heart with a light-sheet microscope (mesoSPIM) at 3.25 × 3.25 × 3 µm; fiber orientation quantified at 96 µm.
Biventricular mesh of ≈328,000 nodes, average edge 150 µm; time step 1 ms; 5 beats simulated, about 2000 s of computing per heartbeat on two 24-core CPUs.
Electrical activation from an eikonal model (electrical conductivity along fibers set to twice that across them); active tension from the RDQ20-MF model (20 equations; Ta = aXB · G([Ca²⁺], SL)).
Passive tissue: Usyk material law; springs and dampers (Robin conditions) for the pericardium; blood circulation as a 0D closed-loop circuit.
Electrical and activation parameters calibrated on measurements from the same specimen; circulation parameters from literature data.
Rule-based fibers: Laplace–Dirichlet rule-based method (LDRBM) of Doste et al., with angles taken from this heart’s own measured distribution.
Topics in this iPaper
Biology
This approach provides high-resolution information on the three-dimensional organization of the myocardium, including the longitudinal and sheet directions of cardiomyocytes, across the entire mouse heart.
Section 2.2 Fibers measurement, page 8
Engineering
The electromechanical model consists of multiple core modules, each representing different physical processes: electrophysiology, activation, mechanics, and blood circulation.
Section 2.5 Electromechanical model, page 11
Mathematics
The multiphysics problem is discretized on a tetrahedral mesh composed of 328 000 nodes
Section 2.5.2 Numerical Implementation, page 14
Medicine & health
To integrate cardiac computational models into routine clinical practice, it is essential to validate the modeling strategies proposed in the scientific literature.
Author summary, page 2
cardiac electromechanics
A high-fidelity biventricular electromechanical model of a murine heart was developed using a high-resolution myocardial fiber field obtained via mesoscopic optical imaging
Abstract, page 1
myocardial fiber architecture
This study investigates the respective roles of macroscopic fiber architecture and microscopic fiber disarray in cardiac electromechanical simulations.
Abstract, page 1
rule based fiber methods
The Doste et al. RBM [50,52] surrogates the fiber architecture by interpolating specific angular values of α and γ at the epicardium and endocardium
Section 2.4 Prescribing the fiber orientations via LDRBM, page 10
finite element method
an in-house high-performance C++ Finite Elements (FE) library focused on cardiac applications based on deal.II FE core
Section 2.5.2 Numerical Implementation, page 14
light sheet microscopy
Cleared hearts were imaged using a modified mesoscopic selective plane illumination microscope (mesoSPIM)
Section 2.2 Fibers measurement, page 8
cardiac digital twins
relevant for the construction of cardiac digital twins, where fiber architecture is typically approximated rather than directly measured
Section 4 Discussion, page 23