Text from the interactive explanation
Multi-resolution deconvolution
Mirza Karamehmedović, Pierre Maréchal, Martin Sæbye Carøe, Lara Baalbaki
Interactive guide · Inverse Problems, 2026
Showing the sharpness lens · preparing the simulation…
Drag the amber lens or tap where it should go; with the picture focused, arrow keys move it.
A blurred, noisy test image, reconstructed with fine resolution inside the amber lens and coarse resolution outside (β = 0.8 and 6.4 pixels, the numbers the paper uses, here on a smaller grid). The large circle magnifies the lens. “Compare” swaps in a single uniform setting, β = 2.5 pixels, the paper's uniform choice. Noise amplification κ: a 1% error in the data becomes about a κ% error in the picture, so lower is calmer.
Live simulation of the paper's formula · our parameter choices
Un-blurring a picture always trades sharpness against noise: ask for finer detail and tiny measurement errors get blown up too. Classical methods pick one sharpness setting and spend it evenly everywhere. This paper lets the setting vary from place to place, so a region you care about comes out sharper than any uniform setting would allow, while the overall noise amplification stays at the same level.
Based on Multi-resolution deconvolution by Mirza Karamehmedović, Pierre Maréchal, Martin Sæbye Carøe and Lara Baalbaki · Inverse Problems 42, 075004 (2026) · open access, CC BY 4.0
01 · The problem
A blur is a smear.
Start with the simplest picture there is: a line with two narrow, bright pulses side by side, like two stars that are close together. This is the paper's own one-dimensional test signal.
A blur replaces every point by a little bell-shaped smear of itself, and where smears overlap they add up. Mathematicians call this smearing a convolution, and the bell shape is the blur's kernel. Widen the blur and watch the two pulses melt together.
Merged into one bump
Live simulation of the paper's formula · our parameter choices
Wiggle-speed: the language of blur
Any signal can be built by adding up smooth waves that wiggle at different speeds. Wiggle-speed is what scientists call frequency . Slow wiggles describe broad shapes; fast wiggles carry fine details, such as the narrow gap between our two pulses.
A blur turns down the volume of the fast wiggles, and the faster the wiggle, the quieter it gets. The curve shows how much of each wiggle-speed survives the current blur. Fine detail is not lost outright. It is turned down, often to almost nothing.
02 · Why it is hard
Undoing a blur is a trap.
If a blur only turns volumes down, why not turn each wiggle back up by exactly the same factor? That is exact un-blurring, or deconvolution . But real measurements always contain a little noise.
Predict first
Our blurred data contain noise of one part in ten thousand, invisible to the eye. If we undo the blur exactly, what happens?
Choose an answer to see what happens.
So we have to stop somewhere. Here the highest wiggle-speed we trust rises and falls by itself: everything faster is thrown away, everything slower is turned back up exactly. Watch the edges sharpen, and then watch the noise erupt.
Noise amplification κ ×0.25
Noise amplification κ compares relative errors: if the data are off by 1%, the reconstruction is off by about κ%. The paper uses exactly this ratio as its “global stability indicator”.
Live simulation of the paper's formula · our parameter choices
When a tiny change in the data can cause a huge change in the answer, mathematicians call the problem ill-posed . Every practical method therefore needs a principled compromise between detail and noise, known as regularisation . Simply chopping off fast wiggles is the crudest kind.
03 · The classical compromise
Aim a little lower: one dial for sharpness.
The paper builds on a regularisation idea called mollification (to mollify is to soften). Instead of demanding the exact truth, aim for the truth as seen through a tiny smoothing bump, a mollifier. The bump's width is the paper's resolution level β , and it is the one dial. A narrow bump asks for fine detail and gets noisy; a wide bump asks for less and stays calm. The “variational” form used in the paper blends both wishes into one filter that never divides by a vanishing number.
Noise amplification κ 0.6 budget 3.2
Challenge
Separate the two pulses without going over the noise budget. The budget, κ ≤ 3.2, is what the setting β = 0.002 costs, similar to the paper's ≈ 3.
Merged · within budget
Live simulation of the paper's formula · our parameter choices
In wiggle-speed terms, the reconstruction multiplies each wiggle ξ of the data by
pβ(ξ) = γ̂(ξ)·φ̂(βξ) / ( γ̂(ξ)² + (1 − φ̂(βξ))² )
where γ̂ is how much the blur keeps and φ̂ is the mollifier's own profile (we use a Gaussian bump, φ̂(t) = e−π²t²; the paper leaves the shape open). Where the blur keeps a lot, p ≈ 1/γ̂ and the blur is undone. Where it keeps almost nothing, the second term in the denominator takes over and quietly shuts the door, instead of dividing by almost zero.
With one dial for the whole signal you can have separated pulses or a calm reconstruction, but not both.
04 · The paper's idea
Let the dial depend on place.
Here is the paper's central move: replace the single number β by a function β(x) that changes with position x. The filter then depends on where you are and on the wiggle-speed at the same time. Mathematicians call such a position-and-frequency recipe a pseudodifferential-type operator. Below, β(x) is the dashed teal line: coarse everywhere (0.0125, the paper's value) with one narrow dip of width 1/20 (also the paper's) where we ask for fine detail.
Noise amplification κ – budget 3.2
Waiting for the simulation…
Live simulation of the paper's formula · our parameter choices
A map of where detail is recovered
This map runs across the line (position) and up in wiggle-speed. A patch glows where the reconstruction recovers that wiggle-speed at that place. With one global dial the glow is a flat plateau. The dip raises a narrow tower: more wiggle-speeds are recovered there, and only there.
Why it works: a Heisenberg-flavoured budget
The noise bill is roughly the glowing area, weighted by how loudly each patch amplifies noise (the warm tint). A tall but narrow tower can cost about as much as a low but wide plateau. In the authors' words, stability depends not only on how far up in frequency you go but also on the size of the region where you do it, “a variation on a Heisenberg theme”: “reaching high frequencies should therefore be possible on regions of interest of limited size.”
Try it somewhere new: drag the dip to an empty stretch of the line and balance again. The tower is just as tall, but there is nothing there to reveal. Sharpening pays off only where fine detail actually exists. In the paper the region of interest is chosen by hand.
05 · In an image
Two dimensions: a scanning lens.
The same idea works for pictures. Our test image is the Shepp–Logan “phantom”, a standard stand-in for a medical scan, given two small bright dots as in the paper. We blurred it by 3 pixels and added 1% noise, mirroring the paper's experiment on a smaller grid. Inside the amber lens β is small (fine detail); outside it is large. This piecewise-constant choice is the one the paper uses.
Close-up around the lens
“Gap” measures how deeply the brightness drops between the two dots, relative to their height above the background: 100% means fully separated, 0% means a single blob (“out of view” when the dots are outside the close-up).
Mini-game · find the twin dots
Somewhere in the image are two tiny bright dots close together. In the data they are a faint double smudge. Steer the lens onto them and make them separate.
Not found yet
“Balance” tunes β inside so the lens has exactly the noise amplification of a uniform β = 2.5 (the paper's uniform choice): κ = 0.185 in our simulation.
The paper's scan, replayed
The tour visits the six lens positions of the paper's Figure 5, from the bright rim at lower left to the rim at lower right, keeping β fixed (0.8 inside, 6.4 outside). The noise amplification barely moves as the lens travels. The paper reports 0.061–0.069 on its own, larger set-up.
Why not just crop?
Couldn't we simply cut out the small patch we care about and reconstruct only that, with one β? The authors argue that stability gets worse as the region being reconstructed shrinks, so at the same κ the cropped patch has to be blurrier. Their Figure 6 makes the point with a square of the same area as the lens. Press “Why not just crop?” to run that comparison here.
Crop comparison not run yet.
Live simulation of the paper's formula · our parameter choices · κ values are our simulation's, not the paper's
06 · The paper's results
What the authors proved, and showed.
A recipe that looks good in a demo is not yet a method. The paper's main work is mathematical: four theorems show that the variable-resolution formula is a sound regularisation method, meaning it behaves well as data get better and resolution is refined.
Theorem 1
It always gives an answer
At every position the formula produces a definite value, even for very rough blurs, including blur kernels that are generalised functions (“distributions”) rather than ordinary curves.
Theorem 2
Refine it and you reach the truth
Scale the whole resolution profile down together (β(x) replaced by α·β(x), with α shrinking to zero) and, for exact data, the reconstruction converges to the true signal at every point.
Theorem 3
Local sharpness buys local accuracy
With noisy data, the error at a point x is of order (α·β(x))d + E, where E is the noise level and d reflects the mollifier. Finer resolution at a place means a smaller blur error at that place, for sufficiently regular signals.
Theorem 4
A guaranteed trade-off
As resolution is refined, the noise amplification stays below a constant times (α·min β)−(n+b), where n is the number of dimensions and b says how fast the blur suppresses fine detail. The guaranteed bound is set by the finest resolution used anywhere, and the constant by the blur, the mollifier and the size of the domain.
Variable-resolution reconstruction (the paper's eq. 3/5):
Rα,βg(x) = ∫ e2πixξ · γ̂(ξ) φ̂(αβ(x)ξ) / ( |γ̂(ξ)|² + |1 − φ̂(αβ(x)ξ)|² ) · ĝ(ξ) dξ
Global stability indicator (section 3.3): c₁ = ‖δg‖/‖g‖, c₂ = ‖δf‖/‖frec0‖, κ ≈ c₂/c₁.
Theorem 3: |f(x) − fα,β(δ)(x)| = O((αβ(x))d + E), uniformly in x.
Theorem 4: ‖fα,β,1 − fα,β,2‖ ≤ C (α inf β(x))−n−b ‖g₁ − g₂‖, with C depending on the size of the domain Ω.
The evidence in the paper
The authors' experiments are simulations “intended primarily to illustrate the qualitative behavior predicted by the theoretical analysis”. They measure stability directly with κ. In one dimension, constant and variable resolution both give κ ≈ 3.055, yet only the variable one separates the pulses. In two dimensions the uniform and lens reconstructions both have κ ≈ 0.06, and κ stays between 0.061 and 0.069 as the lens moves.
07 · Back to the lens
Sharpness you can place.
Classical deconvolution hands you one sharpness setting for the whole picture. This paper turns sharpness into something you can place: concentrate it on a region of interest, relax it elsewhere, and keep the global stability under explicit control. The authors describe their framework as a bridge between classical regularisation theory and spatially adaptive reconstruction. Deconvolution itself, as their introduction notes, sits at the heart of problems “ranging from signal and image processing to statistics”.
They also name what comes next: allowing more general blurs, mollifiers and target signals, handling noise whose strength varies across the picture, and treating the noise in the formula as a random (stochastic) quantity.
Tap or click the picture to place the lens yourself.
κ lens – · uniform –
Source
Mirza Karamehmedović¹, Pierre Maréchal², Martin Sæbye Carøe¹, Lara Baalbaki¹. Multi-resolution deconvolution. Inverse Problems 42 (2026) 075004. https://doi.org/10.1088/1361-6420/ae832b
¹ Department of Applied Mathematics and Computer Science, Technical University of Denmark (DTU Compute), Kgs. Lyngby, Denmark. ² Mathematical Institute of Toulouse (Institut de Mathématiques de Toulouse), Paul Sabatier University, Toulouse, France.
© 2026 The Author(s). Published by IOP Publishing Ltd. Open access under the Creative Commons Attribution 4.0 licence (CC BY 4.0). Reproduced figures are cropped from the article, with rewritten captions.
Interactive simulations are our own implementation of the paper's formula with our parameter choices (Gaussian mollifier, grid sizes, noise realisations). Their numbers are our simulation's, not the paper's.
Topics in this iPaper
Mathematics
We provide consistency, convergence and stability results, as well as convergence rates.
Abstract, page 1 of article (PDF page 2)
Computer science
we address deblurring problems and rely on standard tools from numerical analysis to assess the stability of our reconstruction formula
Section 3.1, page 7 of article (PDF page 8)
deconvolution
The deconvolution problem is at the heart of a wide variety of problems in applied sciences
Section 1 Introduction, page 1 of article
inverse problems
This is an ill-posed inverse problem, the regularization of which has been the subject of numerous works.
Section 1 Introduction, page 1 of article
regularization
in section 2 we establish that, under suitable assumptions, the reconstruction formula (3) is a regularization method
Section 1, page 3 of article
pseudodifferential operators
a pseudodifferential-like solution operator with a symbol depending on both the base and cotangent variable
Abstract and keywords, page 1 of article
image deblurring
illustrate the reconstruction of a modified 601 × 601 blurred and noisy Shepp-Logan phantom
Section 3.3, page 8 of article