Why care? Gels like this already carry drugs, host living cells and sit on sensors. If a simple push could speed up or hold back what moves through them, the authors suggest, materials such as wound dressings or local drug-delivery patches might one day have a dial instead of a fixed recipe. To see why that is surprising, start inside the gel.

1 · Background

A solid that is mostly water

A hydrogel is a soft solid made of long polymer chains, tied together into a three-dimensional net that holds a great deal of water. Jelly is an everyday cousin; in labs, hydrogels hold drugs, living cells and sensors. The gel in this study is polyacrylamide (PAAm), a workhorse lab hydrogel.

The holes in the net — the mesh — are only 1–5 nanometres (millionths of a millimetre) across. So how does a dye molecule get through? By diffusion . Every molecule jiggles randomly as water molecules knock into it. No single molecule “knows” where to go, but when one side is crowded, more molecules happen to wander out of the crowd than into it. That net spreading from crowded to empty is diffusion (described by Fick’s law).

Magnified gel slab

Why not just push water through?

In a coffee filter or a water-purification membrane, the pores are thousands of times wider, and a pressure difference drives water straight through. Flowing water carries dissolved molecules with it. That is convection : fast and directional, unlike diffusion.

A hydrogel’s nanometre mesh makes this extremely hard. Permeability measures how easily water can be pushed through a material — and the ranges barely overlap:

How easily water passes (permeability, m²)

The authors give an example: for a 1-mm-thick hydrogel under a modest 100 pascals, diffusion takes on the order of hours, while pressure-driven flow would take days. So transport in gels is normally treated as diffusion only, and tuned the slow way, by changing the mesh or the chemistry when the gel is made.

Pressure would be a far handier dial. So why not just push much harder?

2 · The obstacle Figure 1 · mechanical tests

Push harder, and gels fail

A big enough pressure difference can force water through a gel, but soft gels balloon out and tear, and stiff ones crack. Earlier flow experiments in soft biological gels used tiny pressures of 0.01–1 kPa. (One kilopascal, kPa, is roughly the pressure under 10 cm of water.) So before measuring any transport, the team tested which membranes could survive. Try it:

Intact · bulging ≈ 14.5 mm

Measured Critical pressures (Fig. 1H): brittle + grids 3 kPa, tough alone 9 kPa, tough + grids 24 kPa are stated in the text; the others are read approximately from the bars. Tough-gel bulging is interpolated between points read from Fig. 1G. Illustrative Membrane shapes and cracks.

Ordinary PAAm made with 14–20 wt% acrylamide is either soft or brittle: strength 7–35 kPa, fracture toughness 10–160 J/m². An unusually high 50 wt% packs the chains into dense entanglements that soak up energy: strength 97 kPa , toughness 830 J/m² , and it can be stretched to five times its length.

Two plastic support grids sandwich the membrane and spread the load. Their struts block about 20% of the open area, so the same grids were used in every experiment to keep comparisons fair.

Grids alone (on a brittle gel): fractured at 3 kPa. Toughness alone: bulged at 8 kPa and cracked in a circle at 9 kPa. Together: no bulging, fracture or leak at 24 kPa .

With a membrane that holds, the next question is how to set a steady pressure difference.

3 · The tool

Two ways to push

Throughout the paper, the pressure difference is the donor’s pressure minus the receiver’s: ΔP = Pdonor − Preceiver. Positive means the dye side pushes harder; negative means the clear side does.

Gravity: a column of water Schematic

ΔP = ρgh ≈ +11.0 kPa (initial)

ΔP = ρgh, where ρ is water’s density and g is gravity. The tube held up to 205 mL, an extra height of up to 248 cm; the paper uses 112 cm for 11 kPa. Water slowly seeps through the gel, so the column sinks and the pressure drifts down: the authors’ model estimates a ~4% drop after 120 h at −6 or +5.4 kPa, and ~45% after 600 h at +24 kPa. That is why gravity experiments are labelled by their initial pressure difference.

Regulated air pressure Schematic

A compressor and an electronic pressure controller push air onto the sealed donor chamber and hold a set pressure — and can switch it on a schedule. The team used this setup, with a 3D-printed cell, for the switching drug-delivery test in section 7.

The trace on the right shows the 0 ↔ 11 kPa, two-hour schedule used there.

Now the main experiment: the same dye race, at three initial pressures.

4 · The finding Figure 2 · transport curves

The race, measured

The donor starts with Brilliant Blue FCF, a food dye that is easy to see and to measure with light. The receiver starts clear. Its dye concentration cR rises toward the evenly mixed value cR,∞, so the ratio cR/cR,∞ runs from 0 (nothing has arrived) to 1 (fully mixed).

The team fitted each run with one simple curve, cR/cR,∞ = 1 − e−t/τ. The characteristic time τ is when the receiver is about 63% of the way there: smaller τ, faster transport.

Predict first. With the receiver side’s water about 1.8 m higher (−18 kPa), water seeps backwards through the gel. What happens to the dye?

Two pushes, added together

The authors explain all three curves with one idea: the dye’s total flow is the sum of two parts, Jtotal = Jdiffusion + Jconvection. Switch the pressure above and watch the parts below.

Dots arrived in the receiver: 0

Diffusion always points from more dye to less, at every pressure. Pressure adds a second push from the moving water. Pointing forward (ΔP > 0), it helps. Pointing backward (ΔP < 0), it holds dye back. In the authors’ model, backflow can only carry back dye that has already reached the receiver, which is why transport slows rather than stops.

That model used water permeability and dye diffusivity measured in separate experiments as fixed inputs, and it matched the measured amounts. At +5.4 kPa the modelled convective share grows until it rivals the diffusive share after a few hundred hours; at −6 kPa it is small and negative (Fig. 2K, 2L).

The donor started with 0.03 mg/mL dye; the receiver with plain buffer. Concentration came from light absorbance at 630 nm.

Membrane: tough PAAm, 0.5 mm thick, 1.5 cm² open to flow, held between two support grids.

One chamber held a fixed 10 mL; the other connected to a vertical tube holding up to 205 mL (up to 248 cm of extra height). −18 kPa corresponds to about 1.8 m of water, +24 kPa to about 2.4 m.

For negative pressures the donor was sampled, and the receiver concentration was calculated from conservation of the total amount of dye.

Each run was fitted with cR/cR,∞ = 1 − e−t/τ. The dots on this page were read off the published plots, so they are approximate.

One formula captures the whole range. Why is it 65-fold, and why so lopsided?

5 · Going deeper Figure 2M · Note S1

Why 65-fold, and why not simply 1/ΔP

Put the two pushes into the bookkeeping of two chambers, and the paper arrives at a formula for the characteristic time:

Read it as: τ = (chamber volumes × membrane thickness) ÷ (area × [diffusion term + pressure term]). The diffusion term is always there. The pressure term adds when ΔP is positive and subtracts when it is negative. The two material properties were measured separately: water permeability k = 1.27 × 10−18 m² and dye diffusivity D = 1.32 × 10−11 m²/s (μ is water’s viscosity, A the membrane area, V the chamber volumes).

Characteristic time vs pressure difference

Tap a point to see its value.

If flowing water were the only route, τ would scale like 1/ΔP and shoot toward infinity as the pressure fades. The measured τ instead stays finite at zero pressure, because diffusion still works, and climbs steeply as backflow increasingly opposes diffusion. That lopsided shape is the fingerprint of two pushes acting together. Across −18 to +24 kPa, the paper reports a tuning range of up to 65-fold .

With no pressure, a thicker membrane slows transport roughly with thickness squared, the classic signature of diffusion: τ grew from ~30 h at 0.4 mm to ~720 h at 2.5 mm. But thickness is fixed once the gel is made.

Tuning ratio = slowest τ ÷ fastest τ. Comparison as reported by the authors: most temperature-, field- or deformation-based approaches stay below 5-fold; their earlier stretching-based system reached about 25-fold.

Changing speed is one use. Can pressure also help tell molecules apart?

6 · Beyond speed Figure 3

Pressure as a sorter

Separating molecules matters for filters, sensors and drug delivery. The team measured selectivity as the ratio of two molecules’ τ values: how many times slower the hindered one crosses. They raced pairs that differ in size or in electric charge.

Why would pressure sharpen the contrast? At zero pressure, selectivity reflects how differently the two molecules diffuse. As pressure-driven flow takes over, it increasingly reflects how differently the network lets each one be carried by water. When the network holds one molecule back from the flow more strongly than it slows its diffusion, positive pressure widens the gap. Big molecules get snagged in the mesh; molecules with the opposite charge to the network are held back by attraction. The negatively charged gel was weaker, so it was tested only to ±7 kPa.

Last step: can pressure decide when a drug gets through?

7 · Proof of concept Figure 4

A drug that waits for the pressure

The donor held doxorubicin (DOX), a small drug molecule (1.35 nm) that kills bacteria. The receiver held E. coli bacteria. At 0.5–2 µm the bacteria are hundreds of times wider than the 1–5 nm mesh, and they never crossed at any tested pressure. Only the drug could.

DOX in the receiver reached ~50 µg/mL within 12 h, a level that cut E. coli density by more than 99%. After 60 h, more than 88% of the bacteria were dead.

DOX stayed below 30 µg/mL even after 48 h. After 60 h, more than 67% of the bacteria were still alive.

DOX’s characteristic transport time changed about 10-fold. Without any drug, more than 95% of the bacteria stayed alive, so the deaths came from the delivered drug.

Measured Values reported in Section 2.4 (gravity-set initial pressures).

Program the pressure

In the real test, a pressure controller switched the drug chamber between 11 and 0 kPa every two hours. Build your own 12-hour program (tap a slot to toggle it), then watch the pattern.

So what has been shown, and what is still open?

8 · Fine print

What this shows, and what it doesn’t yet

Initial, not constant, pressures. In the gravity experiments, water seeping through the gel slowly lowers the pressure difference (modelled ~4% after 120 h at −6 or +5.4 kPa; ~45% after 600 h at +24 kPa). Only the regulated air-pressure setup holds pressure steady.

Steady, slow pressure only. The study used steady or low-frequency pressure. Rapid, pulsing pressure like that in blood vessels and tissues is future work.

A simplified model. It treats the gel as uniform, with water permeability and dye diffusivity fixed. It does not resolve local deformation or molecule-scale interactions; with larger molecules or bigger deformations the mesh itself may change.

Limited by strength. The tough gel with grids reached 24 kPa; the charged gel only ±7 kPa. Other gel types will need their own balance of robustness and responsiveness.

Lab demonstrations. Dyes, a protein and a drug acting on E. coli in lab cells. Uses such as wound dressings are possibilities the authors suggest, not things tested here.

About this page. Dots on the charts were read off the published plots, so they are approximate. All drawings are original, and illustrative elements are labelled.

9 · Back to the start

A dial, not just a recipe

Transport through gels has mostly been set once, when the gel is made: choose the mesh, choose the chemistry. This work adds a dial that can be turned afterwards. Same dye, same membrane:

The key was a membrane that would not bulge or break: a tough, entangled gel braced by grids. With it, pressure-driven flow, long dismissed as negligible in gels, turned out to be a powerful way to speed up, slow down and sort molecular traffic. The authors suggest this could guide intelligent wound dressings, localized drug delivery, adaptive tissue-engineering scaffolds, selective biosensors, soft microfluidic devices, and even electrochemical and energy systems. These are possibilities built on a lab demonstration, and the pressure dial now exists to explore them.

Source

Yijie Cheng, Shahd Alnasser, Akhiri Zannat, Zhenda He, Jiayi Zeng, Lenan Zhang, Sungmin Hong, Xinyue Liu. “Hydraulic Pressure-Programmed Molecular Transport in Tough Hydrogels.” Advanced Science 13, e77159 (2026). https://doi.org/10.1002/advs.77159

Michigan State University; Cornell University; U.S. Army Corps of Engineers, Engineer Research and Development Center. Supporting Information (Materials and Methods, Notes S1–S2, Figures S1–S12) accompanies the article.

The article is open access under the Creative Commons Attribution License. All graphics on this page are original drawings; measured points are re-plotted from values read off the paper’s figures, and schematic or illustrative elements are labelled as such.

Topics in this iPaper

Engineering
we constructed an H-cell platform consisting of a donor chamber, a receiver chamber, and a non-porous hydrogel membrane clamped between the two chambers

Section 2.1, page 3

Chemistry
Conventional polyacrylamide (PAAm) hydrogels synthesized with a low monomer concentration

Section 2.1, page 3

Physics
we considered the total molecular flux as the sum of diffusive and convective

Section 2.2, page 4

hydrogels
hydraulic pressure applied across mechanically tough and grid-supported hydrogels enables robust and tunable solute transport

Abstract, page 1

convection
These findings identify pressure-regulated convection as an underexplored mechanism for controlling transport in polymer networks.

Abstract, page 1

diffusion
consistent with a coupled diffusion–convection model

Abstract, page 1

selective transport
applied pressure enhances size- and charge-dependent transport selectivity by up to 5.4-fold

Abstract, page 1

drug delivery
we investigated pressure-programmed antimicrobial delivery of DOX to Escherichia coli (E. coli) cultures