Original paperSourceNo author review
Make your paper interactiveCreate

Text from the interactive explanation

Hybrid Semi-Transparent Perovskite-Photovoltaics and Concentrated Solar-Thermal Harvesting Collectors

Nada A. Alati, Parth H. Arya, Yu Tian, Ashok Reddy, David B. Ritzer, Bahram Abdollahi Nejand, Ulrich W. Paetzold, Bryce S. Richards, Gan Huang

A see-through solar cell above a sun-focusing lens

Can the same patch of sunlight give both electricity and high-temperature heat — without cooking the solar cell?

That is the ambition behind this collector design. Heating makes up nearly half of the energy used in homes and industry, while rooftops and façades offer only so much space for solar panels.

Diffuse share 10% — the cell turns direct and diffuse visible light into electricity; only the direct near-infrared is focused onto the absorber.

Why one sheet can sort sunlight

A solar cell only uses photons with enough energy — above its bandgap . The shorter a photon’s wavelength, the more energy it carries. The perovskite in this study has a 1.6 eV bandgap, which puts its absorption edge at 775 nm , just past the deepest red our eyes can see.

So the sheet acts like a colour gate. Visible light (shorter than 775 nm) is absorbed and becomes electricity — although any energy a blue photon carries above the gap is lost as heat in the cell. Near-infrared light (longer than 775 nm, invisible to us) does not have enough energy and mostly passes straight through, to be used for heat further down.

550 nm: absorbed → electricity (energy above the gap becomes heat in the cell)

Photon energy = 1.6 eV × (775 nm ÷ wavelength). Bar drawn to scale up to 3.5 eV.

What the lab-made module actually does with sunlight

Share of standard sunlight (AM1.5G, direct + diffuse, spectrally weighted) at the 4 cm² perovskite module.

The near-infrared reflection comes mostly from the interfaces of the transparent electrodes (TCO layers). The authors estimate that removing it could raise transmission from 28.6% toward about 40% — their estimate, not a measurement. The module turns 14.2% of sunlight into electricity Measured

The bandgap sets the trade-off. A larger gap leaves more light for heat but less for electricity. In the paper’s theoretical analysis (Supplementary Fig. S11), moving the gap between two ends of the range gives:

At 1.5 eV the cell can, in theory, convert up to ~32.1% to electricity, leaving ~39.4% of the direct light for heat. This study fixed the gap at 1.6 eV (775 nm).

Put the cell where the light is ordinary

Sunlight arrives two ways. Direct light comes straight from the sun’s disc as parallel beams — a lens can focus it. Diffuse light has been scattered by sky and clouds and arrives from all directions; no lens can focus it to a spot.

Concentrating collectors waste all of the diffuse part. Classic hybrid panels instead glue a heat absorber to the solar cell, so the absorber is usually kept below 60 °C to protect the cell’s efficiency — hot heat and good electricity fight each other.

This design puts a ~1 m² semi-transparent perovskite module on top, in front of a flat, ridged Fresnel lens . The cell sees ordinary, unconcentrated sunlight — direct and diffuse — and stays cool. Only the transmitted direct near-infrared is focused onto a 10 × 10 cm absorber about 1.4 m below; the diffuse near-infrared is the only part left unused for heat.

Cell sees ordinary sunlight (direct + diffuse) and stays near 38.5 °C in the model Model; only transmitted direct infrared is concentrated.

Earlier semi-transparent hybrids usually placed the cell near the focus, under concentrated light — still a big heat load, so intensive cooling was needed. Putting the cell before the lens gives thermal decoupling : the cell stays cool while the absorber gets hot. The authors note that this general layout had been shown before with CdTe and silicon cells; their contribution is implementing and analysing it with semi-transparent perovskites. The lens’s geometric concentration ratio is about 99.

One practical catch: a lens only focuses the sun if it points at it, so a real collector needs a two-axis sun tracker . The study used a lab solar simulator, with no tracker (more on this in section 06).

Before trusting the model, they ran water through the plate

The team 3D-printed the absorber in aluminium alloy, with the same geometry and built-in channels as the real one, and put it under a solar simulator — a lab lamp reproducing sunlight (AM1.5, class AAA). Water flowed through by gravity from a tank; a valve set the flow, a measuring cylinder and stopwatch measured it, and K-type thermocouples logged the temperature going in and coming out.

This tested the absorber alone, deliberately simplified compared with the final design:

water instead of heat-transfer oil

matte black paint instead of the selective coating

air-filled acrylic (PMMA) chamber instead of vacuum

no insulation

no concentration — “a prototype under no concentration conditions”

Its purpose: to check the heat-transfer and fluid-flow computer model against real measurements.

Predict first: if the water flows 2.5× faster (1.5 → 3.8 kg/h), what happens?

Pick an answer (optional) — then check it against the measurements below.

Flow 1.5 kg/h · inlet 16.7 °C (stated in the text) · outlet ≈ 21.8 °C

Temperature rise vs flow

Measured ≈ values, read from Fig. 3c

Heat-collection efficiency vs flow

Measured ≈ values, read from Fig. 3d

The heat rectangle

Area ∝ flow × temperature rise ∝ heat carried away (the paper’s Eq. 2). The shapes change a lot; the areas barely do. Selected: ≈ same area

Why the efficiency barely moves

The lamp delivers about the same heat every second. Faster flow spreads that heat over more water, so each kilogram warms less — more than doubling the flow cuts the temperature rise by more than half, yet the heat collected stays nearly the same and even inches up.

A plausible reason for that slight rise: heat leaks from a surface by convection and radiation in proportion to how much hotter it is than its surroundings — the paper’s loss equations q = h(T − Tamb) and εσ(T⁴ − Tamb⁴). A cooler-running absorber therefore loses a little less. (This is our reading of the trend, not a claim the authors make about this figure.)

The paper’s Eq. 2: useful heat carried by the fluid ÷ sunlight arriving on the receiving area. The computer model matched these measurements within 4% . The test covers only the flows the rig could reach and, as the authors note, “is not intended to determine the upper limit of thermal efficiency”. That validated model is what predicts the full collector next.

Cool cell, hot output

Now the full 1 m² collector, simulated: ray optics plus coupled heat-transfer and fluid-flow modelling, under standard sunlight of 1000 W/m² (about 90% direct), with 25 °C air, a 1 m/s breeze and heat-transfer oil entering at 30 °C.

Oil enters at 30 °C. Thermometers share one scale, 0–160 °C.

Why electricity holds at 13.8%: the cell stays at ≈ 38.5 °C whatever the flow. With the measured 14.2% efficiency and −0.23 %/K temperature coefficient (paper’s Eq. 1):

Optical check: the model’s power absorbed in the perovskite and in the absorber (520 W and 264 W) matched hand calculations exactly, under idealised lens and absorber settings. Its ray tracing shows the lens sending the transmitted light onto the absorber with no stray rays, as a square spot brightest at the centre.

Why ~20% here but ~75% in the water test?

Different denominators. In the lab, the lamp shone straight onto the absorber, so efficiency compared the heat to the light falling on the absorber itself. For the full collector, Eq. 2 divides by all the sunlight on the 1 m² front pane — most of which never reaches the absorber.

Water test Measured

heat ÷ lamp light on the 10 × 10 cm absorber · water, 1.5–3.8 kg/h

Full collector Model

heat ÷ all sunlight on the 1 m² pane · oil, 2.9–7.5 kg/h

Where the sunlight on the 1 m² pane goes — widths roughly proportional; only the labelled numbers come from the paper.

Note the different flows: the lab test used water at 1.5–3.8 kg/h; the model uses oil at 2.9–7.5 kg/h. Measured component values behind the model: lens transmittance 88.5% (for light passing the perovskite), glazing glass 92.0%, absorber coating absorptivity 94.8% and emissivity 0.23 Measured

Swap in better see-through cells

The team re-ran the model with semi-transparent perovskite cells published by other groups: SPV2 (Naqvi et al., 2023) and SPV3 (Nakamura et al., 2022), alongside their own SPV1 . Their transmittance beyond 1300 nm was not available, so SPV1’s spectrum was used there.

SPV1: electricity 13.8% + heat 20.7% at 100 °C output (model)

Cell efficiency published input · SPV1 measured

Average transmittance published input · SPV1 measured

Collector electricity Projected

Collector heat at 100 °C output Projected

Projected model using other groups’ published cells. SPV1’s collector values are the same validated model (13.8% electricity; 20.7% heat when delivering 100 °C).

Cloudier skies Model

Varying the diffuse share of sunlight between 10% and 50% does not change the electrical efficiency — the cell uses diffuse light as well as direct — while the thermal efficiency falls roughly linearly as the diffuse share rises.

Hotter still? Model

With better insulation, much higher temperatures are possible in principle, using molten salts or liquid metals as the fluid. The authors add that integrating record perovskite cells (above 26%, opaque) “offers the potential” to lift electrical efficiency toward ~25% — though semi-transparent cells generally can’t reach opaque-cell efficiency; the best semi-transparent cell here, SPV2, is ≈ 22%.

Aim matters

The lens must face the sun squarely, so a working collector needs two-axis tracking . The paper gives a first-order estimate of what small aiming errors cost: the focused spot slides across the absorber, 1.4 m below the lens, and part of it spills off the 10 cm plate. The perovskite, sitting in ordinary sunlight, barely notices.

A 15 cm receiver would tolerate about 1° — but a larger receiver also loses more heat.

Perfectly aimed (0°): the focused spot lands squarely on the 10 cm absorber — the case the model assumes.

The full collector hasn’t been built yetThe 4 cm² perovskite module and the optical parts were measured, and the absorber was tested without concentration; the whole system’s performance comes from the validated model. It assumes a 1 m² module performs like the 4 cm² one, ignores busbar and frame losses, and assumes perfect alignment with light hitting the lens straight on.

Perovskite durabilityLong-term stability against UV light, humidity and repeated heating and cooling still needs work.

Dust ModelDust dims both the cell and the lens, and focused light must pass both, so heat suffers more (first-order estimate): Dust loss on cell and lens5%10%20%Electrical output−5%−10%−20%Thermal input≈ −9.8%≈ −19.0%≈ −36.0%

Fixed colour split, unknown costThe bandgap was fixed at 775 nm in this study. Cost and payback time still need a detailed techno-economic study.

Not a universal replacementThe authors position this as an early-stage co-harvesting concept for space-limited situations that need both electricity and heat — not a replacement for ordinary solar panels or for separate solar-electric and solar-thermal systems. If you only want electricity, opaque high-efficiency panels remain preferable.

Can one patch of sunlight give electricity and high-temperature heat without cooking the cell?

This work brings that closer. Measured components and a lab-validated model point to a single aperture that could co-produce electricity and heat at roughly 90–155 °C while the solar cell stays cool — a potential the authors present as an early-stage concept, not yet a built 1 m² collector.

of sunlight Model

delivered at 88–155 °C Model

at every modelled flow Model

↑ Back to the sunlight sorter

Source & credits

Alati, N. A., Arya, P. H., Tian, Y., Reddy, A., Ritzer, D. B., Abdollahi Nejand, B., Paetzold, U. W., Richards, B. S., & Huang, G. (2026). Hybrid Semi-Transparent Perovskite-Photovoltaics and Concentrated Solar-Thermal Harvesting Collectors. Advanced Science, e78362. https://doi.org/10.1002/advs.78362 · open-access PDF (PMC13683880)

Institute of Microstructure Technology and Light Technology Institute, Karlsruhe Institute of Technology (KIT), Germany. Open access under the Creative Commons Attribution (CC BY 4.0) licence; © 2026 The Author(s), published by Wiley-VCH GmbH.

All graphics on this page are original drawings coded for iPaper.ai from data and descriptions in the article and its supporting information; no figures were reproduced. Figure 3 values are read from the published plots and approximate.

Topics in this iPaper

Engineering
This study presents a hybrid semi-transparent perovskite-photovoltaic and concentrating solar thermal (SPV-CST) collector designed to maximize solar energy utilization through spectral splitting.

Abstract, page 1

Physics
The comprehensive simulation integrates two primary physics: ray optics and conjugate heat transfer and fluid dynamics

Section 2.3 Modeling and Theoretical/Experimental Validation, page 5

perovskite solar cells
We fabricated and tested a small-sized perovskite module (4 cm2) comprised of 7 monolithically-interconnected solar cells

Section 2.2 Characteristics of the Key Components, page 4

photovoltaic thermal collectors
Hybrid PV-thermal collectors offer a potential solution for more efficient solar energy utilization by co-generating electricity and heat.

Section 1 Introduction, page 2

spectral splitting
The SPV module effectively splits the solar spectrum at 775 nm.

Section 2.2, page 4

concentrated solar thermal
These transmitted photons are then concentrated by the Fresnel lens onto a concentrated solar thermal (CST) absorber, which generates high-temperature thermal energy.

Section 2.1, page 2

ray tracing
Geometrical optics simulations are used to assess the ray tracing within the SPV-CST collector

Section 2.4 Performance Assessment, pages 6-7

conjugate heat transfer
The internal CST absorber is modeled using conjugated heat transfer and fluid dynamics

Section 2.3, page 6